Show simple item record

dc.contributor.authorYukhalang, Sawaten_US
dc.contributor.authorสวัสดิ์ ยุคะลังen_US
dc.date.accessioned2020-01-07T03:42:00Z
dc.date.available2020-01-07T03:42:00Z
dc.date.issued2020-01-07
dc.identifier.issn1906-0432
dc.identifier.urihttp://repository.rmutp.ac.th/handle/123456789/2877
dc.descriptionวารสารวิชาการและวิจัย มทร.พระนคร, 12(1) : 137-146en_US
dc.description.abstractThe effects of load frequency control (LFC) of interconnected distribution power system in tie-line substation area, load –frequency stability and the frequency respond at distribution generator (DG) are very important for interconnected control power system of tie-line area. The generating power system of solar farm and wind turbine which have interconnected distribution power system in tie-line substation area were tested using 3 simulation parameters: non-controller, Automatic Voltage Regulator (AVR) and with Pl Controller. The results showed that there were 3 types of load and frequency changing in the interconnected area: load changed 0.02 p.u. had frequency of load changed 0.025 Hz and large disturbance. Comparisons of load-frequency to respond for steady state, the time respond was 7.9 seconds for non-controller, 5.4 seconds for AVR and 1.7 seconds for under controlled system at 0.1 p.u using Pl controller. Therefore, the Pl controller has better efficiency than non-controller about 31 % and AVR about 16%. It can be concluded that the interconnected distribution power system in tie-line substation area controlling for storage for connected grid had better efficiency and optimization of generating power from renewable solar farm and wind turbine which have interconnected distribution power system in the nearby are balance of controlling of the original system.en_US
dc.description.sponsorshipRajamangala University of Technology Phra Nakhonen_US
dc.language.isothen_US
dc.subjectFrequencyen_US
dc.subjectความถี่en_US
dc.subjectConnectionen_US
dc.subjectการเชื่อมต่อen_US
dc.subjectelectricityen_US
dc.subjectไฟฟ้าen_US
dc.subjectSolar Farmen_US
dc.subjectโซล่าร์ฟาร์มen_US
dc.subjectwind turbineen_US
dc.subjectกังหันลมen_US
dc.titleLoad frequency control of solar farm and wind turbine for interconnected power systemen_US
dc.title.alternativeการควบคุมความถี่ -โหลด ของการเชื่อมต่อระบบการผลิตไฟฟ้าจากโซล่าร์ฟาร์มและกังหันลมen_US
dc.typeJournal Articlesen_US
dc.contributor.emailauthoryu_sawat@hotmail.comen_US
dc.contributor.emailauthorarit@rmutp.ac.then_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record