dc.contributor.author | Charlangsut, Aroon | |
dc.contributor.author | Boonthienthong, Manat | |
dc.contributor.author | Thongkeaw, Somkieat | |
dc.contributor.author | Boonchiam, Paisan | |
dc.date.accessioned | 2010-02-28T15:32:23Z | |
dc.date.available | 2010-02-28T15:32:23Z | |
dc.date.issued | 2008-08-27 | |
dc.identifier.citation | 15th International Symposium on High Voltage Engineering ISH 2007 | en_US |
dc.identifier.uri | http://repository.rmutp.ac.th/handle/123456789/334 | |
dc.description | This paper proposes a study of an Ozone generator. The generator under the study is designed using the electrode with uniform field. | en_US |
dc.description.abstract | This paper proposes a study of an Ozone generator. The generator under the study is designed using the electrode with uniform field. The electrode is constructed in the plane shape with positive potential. The transformer oil is used as insulating materials to prevent discharges around the electrode discharges in the air void depends on the size, the types of dielectrics and level of applied voltage. Between the electrode and the air void, there is acyclic dielectric. The stainless electrode with water is used as a ground potential. The breakdown depends on the electric field intensity. It is found that there is sufficient amount of ozone due to the ionization, Development and design ozone generator this research electric field intensity on the water type and this can be used as a principle to construct a new type of ozone generator. | en_US |
dc.language.iso | en_US | en_US |
dc.publisher | ISH 2007 | en_US |
dc.subject | electrode | en_US |
dc.subject | electric field | en_US |
dc.subject | dielectric | en_US |
dc.subject | ozone | en_US |
dc.title | Study of Ozone Generator with Electric Fields Distribution on Water Surface | en_US |
dc.type | Journal Articles | en_US |
dc.contributor.emailauthor | eng@rmutp.ac.th | en_US |
dc.contributor.emailauthor | arit@rmutp.ac.th | |