Increasing steam boiler efficiency from stack inside heat recovery by heat exchanger economizer technology and maintenance
Abstract
The objectives of this study is to increase efficiency of steam boiler 2.5 ton
per hour which used liquid petroleum gas LPG as fuel. bringing heat recovery inside
boiler chimney stack to preheat feed water with technology heat Exchanger
Economize. Taking the economizer with its pipe length of 1,000 mm and 62 mm
diameter for 64 pipe is a cross flow with staggered tube to increase water
temperature before entering the boiler pass to deaerator The study is carried out to
compare the differences and savings of the feed water temperature, steam boiler
efficiency, and fuel consumption between having the economizer installed and
uninstalled. reference to study The result after installed the heat exchanger
economizer the feed water is passed into steam boiler deaerator higher temperature
from 38.30°C to 67.20°C which leads to increase efficiency of steam boiler from
81.59 % to 85.65 % meaning that the fuel consumption of steam boiler will be
reduced 4.97 %
Collections
- Independent Study [31]