dc.description.abstractThis paper presents a study of comparison of PWM power rectifier between 6 Pules and 12 Pules converter topology by small hydro turbine Generator (20kW) is power supply and Compare harmonics Current feed in the systems. Both converter connected Permanent Magnet Synchronous Generator (PMSG) and Voltage Regulator Control at 700 V. The control system by Decoupling Control and Conventional PI Control for control parameter PI value by Nicole-Ziegler method. Analysis for Performance of the system presented a mathematical model with Matlab/Simulink program. The result of simulation have value less than 5 percent of ripple voltage and Voltage Control continuously. Converter 12 pulse have harmonics Current value feed in the systems less than converter 6 pulse. This Case study can apply using PWM power rectifier control in future worken_US
dc.description.sponsorshipRajamangala University of Technology Phra Nakhonen_US
dc.language.isothen_US
dc.subjectPower Rectifieren_US
dc.subjectวงจรเรียงกระแสกำลังen_US
dc.subjectPermanent Magnet Synchronousen_US
dc.subjectเครื่องกำเนิดไฟฟ้าแบบแม่เหล็กถาวรen_US
dc.subjectGenerator and PI Controlen_US
dc.subjectการควบคุมพีไอen_US
dc.titleComparison of PWM power rectifier between 6 pules and 12 pules converter topologyen_US
dc.typeJournal Articlesen_US
dc.contributor.emailauthorkrischonme.b@en.rmutt.ac.then_US
dc.contributor.emailauthorarit@rmutp.ac.th
dc.contributor.emailauthorarit@rmutp.ac.th


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record