dc.descriptionThis paper presents risk assessment of damages for equipments in the building based on IEC standards and ITU-T recommendations. The study of risk assessment of damages for equipment in the building includes of 6 main topics: calculation of frequency of damages due to lightning discharges, calculation of risk of damage, calculation of risk areas, estimation of probability factors, consequential damage.en_US
dc.description.abstractThis paper presents risk assessment of damages for equipments in the building based on IEC standards and ITU-T recommendations. The study of risk assessment of damages for equipment in the building includes of 6 main topics: calculation of frequency of damages due to lightning discharges, calculation of risk of damage, calculation of risk areas, estimation of probability factors, consequential damage factor, acceptable risk levels and mitigation methods to reduce the influence of power line induction affecting to equipment. Also, the implementations of surge protective devices (SPDs) at the entrance of power lines into the building contribute to a further decrement of damage.en_US
dc.language.isothen_US
dc.publisherRajamangala University of Technology Phra Nakhonen_US
dc.subjectLightning Dischargeen_US
dc.subjectRisk Assessment of Damagesen_US
dc.subjectFrequency of Damages and Risk Areasen_US
dc.titleRisk Assessment of Damages for Equipments in the Buildingen_US