dc.contributor.author | Rugthaicharoencheep, Nattachote | en_US |
dc.contributor.author | นัฐโชติ รักไทยเจริญชีพ | en_US |
dc.contributor.author | Chalangsut, Aroon | en_US |
dc.contributor.author | อรุณ ชลังสุทธิ์ | en_US |
dc.date.accessioned | 2020-02-18T08:36:06Z | |
dc.date.available | 2020-02-18T08:36:06Z | |
dc.date.issued | 2020-02-18 | |
dc.identifier.uri | http://repository.rmutp.ac.th/handle/123456789/3156 | |
dc.description | รายงานวิจัย -- มหาวิทยาลัยเทคโนโลยีราชมงคลพระนคร, 2560 | en_US |
dc.description.abstract | To Improvement the power factor is very important. Because the costs are increased or reduced. To Improvement the power factor, the higher the value, it is necessary to buildings, offices and industrial buildings or the fact that the industry needs real power. And reactive power source to operate.
This research presents the design and construction of reactive power factor control. Which amounted to 6 working order by the first sequence is divided into three three-phase electrical power system and three consecutive singles phase by active power different. first1 is reactive at 5 kVAr second 2 and third 3 are reactive at 2.5 kVAr forth 4, fifth 5 and sixth 6, precious marine active 0.83 kVAr control. the power factor controller that controls RG3-12 pay Oval active in various sequences.
As a result, when not equipped with reactive power compensation software to control the power factor. This makes the flow of the high and low Power Factor schedule. When equipped compensate reactive power source to power factor control. Single-phase motor 1 kW and light bulb 1,640-watt making the current
decline of 14 amps rest 12 amps of the power factor increases from 0.5 to 0.929. When connected to three-phase motor with 2 kW 0.8, 2.2 flow down from 2.360 rests 0.942 amps of power factor value up from 0.308 to 1.0. | en_US |
dc.description.sponsorship | Rajamangala University of Technology Phra Nakhon | en_US |
dc.language.iso | th | en_US |
dc.subject | Electric power | en_US |
dc.subject | กำลังไฟฟ้า | en_US |
dc.subject | Power System | en_US |
dc.subject | ระบบไฟฟ้ากำลัง | en_US |
dc.subject | Reactive Power Control | en_US |
dc.subject | การควบคุมกำลังไฟฟ้ารีแอคทีฟ | en_US |
dc.subject | Electric power control | en_US |
dc.subject | การควบคุมกำลังไฟฟ้า | en_US |
dc.subject | power factor | en_US |
dc.subject | เพาเวอร์แฟคเตอร์ | en_US |
dc.title | Reactive power control to improve the economic of power system | en_US |
dc.title.alternative | การควบคุมกำลังไฟฟ้ารีแอคทีฟเพื่อเพิ่มมูลค่าทางเศรษฐศาสตร์ ในระบบไฟฟ้ากำลัง | en_US |
dc.type | Research Report | en_US |
dc.contributor.emailauthor | nattachote.r@rmutp.ac.th | en_US |
dc.contributor.emailauthor | aroon.c@rmutp.ac.th | en_US |
dc.contributor.emailauthor | arit@rmutp.ac.th | en_US |