Show simple item record

dc.contributor.authorYaruang, Piyapongen_US
dc.contributor.authorปิยะพงษ์ ยารวงen_US
dc.contributor.authorKatkhaw, Nopparaten_US
dc.contributor.authorนพรัตน์ เกตุขาวen_US
dc.contributor.authorPudwong, Songpolen_US
dc.contributor.authorทรงพล ผัดวงศ์en_US
dc.date.accessioned2020-09-07T07:17:09Z
dc.date.available2020-09-07T07:17:09Z
dc.date.issued2020-09-07
dc.identifier.issn2651-1096
dc.identifier.urihttp://repository.rmutp.ac.th/handle/123456789/3347
dc.descriptionวารสารวิชาการและวิจัย มทร.พระนคร, 13(2) : 24-36en_US
dc.description.abstractThis research is to study in heat transfer of hot water tank from an air conditioner which is a cylinder type and has a hot water pipe around the tank. It is used for finding a position and a pattern of distribution of the hot water pipe around the tank in the highest heat transfer condition. The study uses the cylinder of hot water tank filled 45 liters of 25 oC water. An experiment separates in 3 positions of pipe wrapping which are the bottom, the center and the top of the tank. Then, 80 oC of hot water run thought the hot water pipe which is wrapped around the tank for 120 minutes. The result of the experiment shows that tubing position that causes the highest heat transfer is at the bottom of tank. Pipe wrapping at the bottom of the tank has the heat transfer higher than the top of the tank at 30%. Furthermore, this experiment studies in spacing of hot water pipe. There are 3 types for testing which are spacing hot water pipe as one time, two times and three times of diameter of pipe. The result illustrates that spacing the hot water pipe can significantly increase the heat transfer. The heat transfer of spacing the hot water pipe in three times of diameter of pipe is higher 5.8 % than spacing in one times. In addition, this research is to study in the effect of turbulent flow on the heat transfer by installing agitator in order to stir water in the tank. The result is that water stirring in the tank for increasing the heat transfer is not effective for investment because the energy using for stirring is higher than the enhanced heat transferen_US
dc.description.sponsorshipRajamangala University of Technology Phra Nakhonen_US
dc.language.isothen_US
dc.subjectHeat transferen_US
dc.subjectการถ่ายเทความร้อนen_US
dc.subjectHeat energyen_US
dc.subjectพลังงานความร้อนen_US
dc.subjectAir conditioningen_US
dc.subjectเครื่องปรับอากาศen_US
dc.subjectHot water production systemen_US
dc.subjectระบบผลิตน้ำร้อนen_US
dc.titleHeat transfer enhancement of a recovery hot water tank from waste heat of condensing uniten_US
dc.title.alternativeการเพิ่มการถ่ายเทความร้อนของถังน้ำร้อนในระบบผลิตน้ำร้อนที่ใช้พลังงานความร้อนทิ้งจากเครื่องปรับอากาศen_US
dc.typeJournal Articlesen_US